Stainless steel curbs, made for washdown.

Works with what you have

Ties into resinous or tile floor systems
Retrofits against existing walls and wall panels
No DELC drain or floor required
The System

Hygienic, durable, smart.

The DELC Sanitary Stainless Steel Curb System is a hygienic, impact-resistant floor-to-wall transition for sanitary processing environments. It eliminates sanitation traps at the wall/floor interface and integrates seamlessly with resinous flooring and stainless drainage.

Spend Less on SanitationSmooth surface, no crevices to scrub
Save Build TimeFabricated to plan, not formed on site
Protect Your WallsAbsorbs forklift and cart impact
Pass InspectionsMeets sanitary design standards
Expected Service Life20–25+ years, minimal maintenance
Configure
Build Your Spec

Configure your curb.

Click through the options to build your spec — it writes itself as you go, and you can send it straight to us.

1

Choose your face height

Not selected
Face height is the curb's quoted dimension — confirm your required height and we'll align it to the 6″ or 10″ face. Not sure which height? Read the comparison.
2

Choose your gauge

Not selected
Not sure which gauge? Read the comparison.
3

Choose your project type

Not selected
4

Choose your material

Not selected
Not sure which grade? Read the comparison.
Your Spec
Why Stainless, Not Coating

Stainless curbs aren't an upgrade. They're a structural necessity.

Three things decide whether a floor-to-wall transition survives a food plant — and coated concrete loses on all three.

Elimination of the bacterial reservoir

The wall/floor interface is where sanitation traps form. Once a coating chips, porous concrete underneath absorbs liquids and harbours bacteria in a joint your crew can't fully reach. Non-porous welded stainless leaves nothing to absorb.

Superior impact resistance

Forklifts, carts, bins and pallets hit the curb constantly. Stainless resists the chips and cracks that expose concrete underneath, so a single impact doesn't start the failure cycle.

Precision engineering vs. field guesswork

A poured or hand-formed curb is only as consistent as the crew forming it. HygieniCurb™ is fabricated to plan — corners, transitions, and terminations built in the shop, not improvised on site.

Total Cost of Ownership

Say goodbye to curb maintenance.

Coated concrete needs recoating every three to five years as chemicals, impact, and wear break the surface down — material costs, labour, and downtime each cycle. Stainless skips that entirely: no coating to degrade, no scheduled shutdowns, just routine cleaning.

Stop Losing Output
No recoating shutdowns
Audit Ready. Always
No coating to fail an inspection
Save Construction Time
Shop-fabricated, faster install
Save Sanitation Labour
Less time and product per wash
Recoating Loss Calculator
What is recoating actually costing you?
Based on a 100 ft curb run. Adjust the levers for your facility — defaults are typical market figures for polyurethane curb recoating.
$0 estimated savings with HygieniCurb™ over 20 years
5 Years
$0
10 Years
$0
15 Years
$0
20 Years
$0
These figures are rough estimates for illustration only, generated from the inputs you set. Actual costs and savings vary by plant, usage, installation conditions and other factors, and are not guaranteed. DELC Manufacturing accepts no responsibility or liability for decisions made based on this calculator — consult us directly for a real spec review before making any purchasing decision.
Head to Head

HygieniCurb™ vs. coated curb.

Seven categories that decide whether a curb lasts a decade or a generation.

DELC HygieniCurb™
Coated Concrete Curb
Expected LifespanTo recoat, or not?
20–25+ years with minimal maintenance
5–10 years before coating failure
Impact ResistanceForklifts, carts, bins and pallets hit the curb constantly.
Resists chips, cracks and damage from equipment
Coating chips and cracks expose porous concrete
Chemical ResistanceFood plants run heavy chemical cleaning cycles.
Withstands harsh cleaners, acids and sanitizers
Degrades with repeated chemical exposure
Surface PorosityAre there harbours for bacteria?
Non-porous stainless — no bacteria harbouring
Once coating fails, concrete absorbs liquids and bacteria
CleanabilityLonger cleaning times mean higher labour and product cost.
Smooth surface, easy to sanitize, no crevices
Cracks and chips create cleaning challenges
Inspector ComplianceYour curbs should keep you inspection-ready at any given time.
Meets all sanitary design standards
Degraded coating fails inspections
Odor AbsorptionWhat the room smells like after years of production.
Avoids odor absorption entirely
Porous concrete absorbs and retains odors
Lifespan and recoating intervals reflect typical performance in food and beverage processing environments. Actual figures vary with washdown chemistry, traffic and facility conditions — not a substitute for a real spec review.
FAQ

Installer questions, answered.

How does the top of the curb connect to the wall panel?

The curb hangs on a French cleat fastened to the wall. Once the concrete core is poured, the curb is locked in place, and the top joint between the curb and the panel is finished with a continuous sealant line.

How does the bottom of the curb tie into the floor coating?

Along the toe, the curb sits on a seal strip with a ¼″ × ¼″ reglet. The urethane cement floor coating is keyed into that reglet and carried about halfway up the curb's angled toe, so the floor locks into the curb rather than relying on a sealant bead at the floor line.

Can HygieniCurb™ be installed in an existing plant?

Yes. HygieniCurb™ retrofits against existing walls and wall panels. It's fabricated to your plan, so there's no forming, grinding or coating of the curb on site.

Do I need DELC drains or a specific floor system?

No. HygieniCurb™ ties into resinous or tile floor systems, and no DELC drain or floor is required. Pairing it with the DELC system does mean one supplier details every drain, curb and floor junction.

Which gauge and grade do I need: 14 or 16 gauge, 304L or 316L?

Use 14 gauge heavy duty where forklifts and pallet jacks run, and 16 gauge light duty for carts and foot traffic. 304L suits most washdown areas, while 316L is for harsher chemicals and chlorides. See our curb gauge guide and 304 vs 316 guide, or send us your conditions.

Better together

Pair HygieniCurb™ with the rest of the DELC system and one supplier details every drain, curb and floor junction. That means fewer hand-offs between trades and one point of contact for the spec.

Ready to Spec?

Send us the room, we'll detail the curb.

Send your floor plan or facility details and we'll turn around a spec-ready quote — corners, transitions and terminations detailed to your layout.